The previous manual level method will cause overpress easily. Therefore, we develop this new method to ensure the correct setting.
Step1: Update the firmware to version 2.0.1.205
AccuFab-D1 firmware update procedure - V2.0.1.205
Step2: Disable the pressure senor and do the manual level
Step3: Print attached test parts and measure heights
Fill in the measured heights in the attached excel to calculate the manual level distance.
Step4: Set the manual level distance
Set the manual level distance base on the overpress/underpress value. For example, if the result is overpressing 0.3mm, then the manual level distance should adjust from 2.0mm to 1.7mm.