AccuFab-D1 Manual Level - New Method

The previous manual level method will cause overpress easily. Therefore, we develop this new method to ensure the correct setting. 


Step1: Update the firmware to version 2.0.1.205


AccuFab-D1 firmware update procedure - V2.0.1.205


Step2: Disable the pressure senor and do the manual level 



Step3: Print attached test parts and measure heights


Fill in the measured heights in the attached excel to calculate the manual level distance.



Step4: Set the manual level distance


Set the manual level distance base on the overpress/underpress value. For example, if the result is overpressing 0.3mm, then the manual level distance should adjust from 2.0mm to 1.7mm.

 