Scene 1: First-Time Use of the Small Build Platform
Leveling Method: Full (Advanced) Leveling
Reason: The small platform has a different Z-height.
(Set to the same Z-axis position as the standard build platform)
Note: After this initial leveling, both the small and standard platforms can be used interchangeably.
Scene 2: Switching Between Standard and Small Platforms (After Initial Setup)
Leveling Method: No additional leveling required
Reason: If full leveling has already been done for both platforms, you can switch between them without re-leveling.
Scene 3: Print Failure Occurs Occasionally
Leveling Method: Quick Leveling
Reason: Minor shifts may occur over time or after frequent use. Quick leveling can correct small deviations.
Note: Only level the platform currently in use.
Scene 4: Frequent or Repeated Print Failures Even After Quick Leveling
Leveling Method: Full (Advanced) Leveling
Reason: Persistent failures may indicate more significant deviation.
Note: After full leveling, both platforms must be leveled again if you plan to use both.